Color temperature Warm white Warm white Warm white Neutral white Cold white
Color temperature, typ 2200 2700 3000 4000 5700
Right, my 80 90 90 90 90
Light flux, min at 350mA 432 lm 412 lm 412 lm 456 lm 496 lm
Luminous flux, typ at 700mA 800 lm 760 lm 760 lm 840 lm 920 lm
Spreading angles - - - - -
- Real spot (RS) 18° 18° 18° 18° 18°
- Medium (M) 24° 24° 24° 24° 24°
- Wide (W) 31° 31° 31° 31° 31°
- Wide wide (WW) 36° 36° 36° 36° 36°
- Wide wide wide (WWW) 45° 45° 45° 45° 45°
- Oval (O) 19x48 ° 19x48 ° 19x48 ° 19x48 ° 19x48 °
Whoa, typ at 350mA 11,3 V 10,8 V 10,8 V 10,8 V 10,6 V
Whoa, typ at 700mA 11,7 V 11,2 V 11,2 V 11,2 V 11,0 V
RthJ-A 10 ° C / W 10 ° C / W 10 ° C / W 10 ° C / W 10 ° C / W
Energy efficiency class F F F F E

Color temperature, Kelvin (K)

1800
2200
2700
3000
4000
5700
More information

More information

Color temperature

, , , ,

CRI

,

Viewing angle

, , , , ,

Documents

Datasheet for Lupus.

Datasheet product

Warranty conditions

Lightronics warranty conditions. The terms apply to all products.

Warranty conditions Lightronic

Energy Labelling
Product information regarding energy efficiency

2200K 2700K 3000K 4000K 5700K


Label for energy efficiency


Obligations for e-commerce

As a seller of light sources, since September 1, 2021, we are obliged to report the energy class of the light source. The class is shown in a gradation from A to G, where A corresponds to the best efficiency. Through the Energy Labeling, it should make it easier for the user to choose light sources based on their energy efficiency. The energy class is shown at this location through the product's energy label. The energy class and efficiency are also reported in the light source's data sheet, which can be downloaded higher up on this product page.


Energy efficiency classes and calculation method

The energy efficiency class for light sources shall be determined according to Table 1, based on light output based on the power from the mains ηTM, which is calculated by dividing the declared usable luminous flux Φuse (expressed in lm) by declared power consumption in position Pon (expressed in W) and multiplying by applicable FTM in Table 2, i.e. ηTM = (/use / Pon) x FTM (lm / W).

Energy efficiency class Light exchange based on the power from the mains ηTM (lm / W)
A 210 ≤ ηtm
B 185 ≤ ηtm <210
C 160 ≤ ηtm <185
D 135 ≤ ηtm <160
E 110 ≤ ηtm <135
F 85 ≤ ηtm <110
G ηtm <85

Table 1 - Energy efficiency classes for light sources


Typ of light source FTM factor
Radiant (NDLS), connected to the mains (MLS) 1,000
Radiant (NDLS), not connected to the mains (NMLS) 0,926
Directed (DLS), connected to the mains (MLS) 1,176
Directed (DLS), not connected to the mains (NMLS) 1,089

Table 2 - Factors FTM per typ of light source